Mining efficiency comparison
Compare two configurations. See the throughput, power and electricity trade-off.
Use sustained hashrate and average whole-PC wall power over matching intervals. Compare the same algorithm variant and workload; raw rates across different algorithms are not comparable. Measurement checklist ↓
Hypothetical example loaded — invented inputs, no measured hardware performance. You can edit every value.
Hashes per joule
HIGHER = MORE EFFICIENTAwaiting measurements
Enter both sets of measurements to compare efficiency. Add a tariff for electricity costs.
Electricity expenditure
Same runtime and tariff for A and B · projections, not bills
| Measure / period | A | B | Difference · B − A |
|---|---|---|---|
| Energy / day | — | — | — |
| Cost / day | — | — | — |
| Cost / 30 days | — | — | — |
| Cost / 365 days | — | — | — |
What the comparison means
Enter sustained hashrate and average whole-PC wall power for both configurations.
Greater efficiency does not guarantee profitability. Your choice depends on goals, measurement reliability, revenue and operating constraints. Differences within normal run variation or meter uncertainty may be inconclusive.
Make the measurements comparable
Use the same algorithm variant, comparable workload, observation intervals and measurement boundaries. Keep software version, background work, thermals and other operating conditions stable. Record sustained rates after warm-up, rather than isolated peaks.
This comparison uses total whole-system power at the wall, including the rest of the PC and power-supply losses. CPU package telemetry and TDP cannot replace wall measurements. Do not mix component-level power with whole-PC power. Incremental mining power subtracts an idle baseline and answers a different question; no idle subtraction is performed here.
Measure whole-PC power and keep the comparable-run worksheet. For profile context, read the CPU threads explanation and RandomX memory/cache explanation.
From watts to energy and cost
Efficiency = (H/s) ÷ wall wattskWh/day = (wall watts ÷ 1,000) × hours/dayCost = kWh/day × tariff × daysB change % = (B ÷ A − 1) × 1001 kH/s = 1,000 H/s. Hashes per joule = H/s per watt. Differences are always B − A, with A as the percentage baseline. Calculations retain full precision; readouts are rounded only for display. Small non-zero values remain visible.
Arithmetic range: 0.000001–1,000,000,000,000 H/s and 0.000001–1,000,000,000 W, with units normalized first. These broad numeric safeguards prevent unusable projections; they are not claims about hardware. Costs assume constant power, runtime and tariff over 1, 30 or 365 days; 30 days is not a calendar month. Zero tariff is valid.
Efficiency is one part of the decision
The explicit example uses hypothetical A = 8,500 H/s at 145 W and B = 7,900 H/s at 105 W, running 24 hours/day at GBP 0.25/kWh. These are invented arithmetic inputs, not benchmarks or hardware recommendations.
This tool compares throughput, energy efficiency and electricity expenditure. It does not model mining revenue, hardware costs, cooling, wear, fees, reward variability or profitability. To explore manual revenue assumptions, use the mining profitability calculator. For one workload’s energy bill, use the electricity cost calculator. To interpret supported console signals, use the XMRig log decoder.
All calculations run locally in your browser. Inputs are neither uploaded nor automatically saved. No live network, market or benchmark data is used.