Mining Electricity Cost Calculator

Estimate what a mining PC or other continuous workload uses and costs to run. Enter your own power measurement and electricity rate; no tariff is assumed.

01 / YOUR INPUTS LOCAL CALCULATION
W100 W is an illustrative starting value only. Replace it with your own wall measurement. Maximum 20,000 W.
Enter the price from your own tariff. For UK pence/kWh, select GBP and p/kWh. Rate maximum: 1,000 per kWh or 100,000 p/kWh.
Runtime
hours / day
Choose a preset or enter any runtime from 0 to 24 hours.
days
Set 1 to 365 days. The yearly view always uses 365 days.
Currency changes display only. No conversion is performed.

Estimated electricity use and cost

02 / ENERGY → COST30 DAYS

The starting 100 W is illustrative. These are entered assumptions, not a live hardware measurement.

POWERSet inputs
ENERGY / DAY—
ESTIMATED COST / DAYEnter a rate
PER HOUREnter a rate
30 DAYSEnter a rate
365 DAYSEnter a rate
ENERGY— / period— / 365 days

Energy updates as you change inputs. Add a rate to see estimated electricity cost.

MEASURE / THEN ESTIMATE

What power value should I enter?

Use average whole-PC power at the wall for the running-cost estimate above. CPU package telemetry and a processor's TDP are not a measurement of the complete computer's electricity use.

Wall socketAC electricity
Plug-in meterWhole-PC W / kWh
INSIDE THE PC
Power supplyConversion losses included at the wall
CPUPackage telemetry: a narrower boundaryOther componentsRAM, board, GPU, storage and fans
The meter sits between the socket and the PC power supply: it includes the supply's losses and everything powered by that PC. A CPU sensor describes a component, not this whole-system boundary. A separately plugged-in monitor is outside the PC reading unless deliberately included and recorded.

A repeatable wall-power reading

  1. Choose the boundary. Use an intact plug-in meter rated for your supply and load, following its manufacturer's instructions. Do not open equipment, modify mains wiring or exceed ratings. Record which devices it powers.
  2. Choose a representative interval. Let the intended workload settle, then note elapsed time and start/end energy readings. Include normal variations; record warm-up separately. A single instantaneous watt reading can miss changes.
  3. Average the interval. Divide the energy difference by elapsed hours, then multiply by 1,000 to get watts. Use a long enough interval for the meter's resolution; record precision and repeat if readings vary. No universal interval suits every meter or workload.
  4. Keep the context. Note workload, settings and other activity. For mining comparisons, use the comparable-run worksheet and match the hashrate and energy windows.

Power is a rate. Energy accumulates.

Watts (W) describe power at a moment or an average over an interval. Kilowatt-hours (kWh) measure energy used over time. TDP is a processor design specification, not a wall-meter result for your workload.

HYPOTHETICAL ARITHMETIC · NOT HARDWARE DATA

Suppose a meter records 0.09 kWh over 30 minutes. That is 0.5 hours:

0.09 ÷ 0.5 × 1,000 = 180 W average

Holding that average for 8 hours would use 1.44 kWh. At an invented £0.25/kWh, the estimated cost is £0.36. The future hours and tariff are assumptions; the numbers here are a teaching example, not measurements.

Total running cost or extra mining cost?

TOTAL ACTIVE POWER

Use the whole active PC reading for its running cost. This includes its baseline consumption as well as the workload.

ACTIVE MINUS MATCHED IDLE

The difference estimates extra load relative to that idle state. Keep devices, settings and observation conditions matched; if the difference is within meter uncertainty, it is inconclusive.

Idle means the defined comparison state with mining stopped, not zero watts. If the PC would otherwise be switched off, a logged-in idle baseline is not the alternative. Do not silently substitute incremental watts for total watts in the calculator above.

Use your own tariff's unit rate

Take the electricity price per kWh from your current bill, contract or supplier account, including applicable taxes. Keep it in the selected currency: GBP pence/kWh needs the pence option; £0.25/kWh and 25p/kWh describe the same rate. Currency selection does not convert money.

For peak/off-peak rates, calculate each period with its own rate and runtime and add the costs. Standing charges are normally payable independently of this PC's use; the calculator does not include them. A new supply or contract solely for mining changes that cost boundary. Ofgem explains regional and multi-rate tariff context for Great Britain; it is not a universal UK price or your personal tariff.

REUSE / COPY OR PRINT

A small measurement record

Copy these labels into your own notes, or print this page. Leave missing measurements as unknown; no values are stored or uploaded here.

Hardware configuration
CPU, RAM, graphics, peripherals and power settingsRecord: __________________ / unknown
Measurement boundary
PC only, or name every device included at the socketRecord: __________________ / unknown
Observation duration
Start/end time and elapsed hours; warm-up recorded separatelyRecord: __________________ / unknown
Recorded energy
Start/end kWh readings and their differenceRecord: __________________ / unknown
Average wall power
1,000 × interval kWh ÷ elapsed hours, in wattsRecord: __________________ / unknown
Idle or active state
Mining stopped, or exact workload/version/profileRecord: __________________ / unknown
Measurement notes
Meter model/resolution, background work, temperatures; mark unknownsRecord: __________________ / unknown

Method references checked 25 November 2026: Energy Saving Trust: power and energy units; Intel: TDP is a thermal design target. The averaging and record workflow is Ember's proposed measurement method, not a report of hardware testing.

Once both runs have matching hashrate and wall-power measurements, use the mining efficiency comparison to compare hashes per joule and electricity expenditure.

METHOD / 01

How the calculation works

Watts are converted to kilowatts, then multiplied by the hours the system runs. Energy in kilowatt-hours is multiplied by your entered electricity rate.

kWh = (watts ÷ 1,000) × hoursCost = kWh × price per kWh

Hypothetical arithmetic: a constant 100 W load running 24 hours would use 2.4 kWh/day. Multiply that energy by your own price per kWh to estimate daily cost; this is not a hardware measurement.

The day uses your runtime. The selected period uses your chosen number of days. The yearly estimate uses 365 days. Values are calculated without rounding and rounded only for display.

CONTEXT / 02

Why mining electricity use matters

Continuous workloads accumulate energy over time, and part-time operation changes the estimate directly. A measured whole-system value gives a better household-cost estimate than CPU package power alone.

Electricity is one part of mining economics. This tool intentionally estimates energy and electricity cost only; it does not estimate mining income or profitability. For a manual expected-value scenario, use the Monero Mining Profitability Calculator.

Understand the memory used by RandomX

Considering Ember alongside your estimate? See what the in-development Windows app currently supports.